Museum of the core part of the security system is anti-theft as core, its purpose is to prevent crime from occurring and to identify risk effectively, but the alarm system background software exist interface single, lack of sound and image data, real-time verification; CCTV system can be solved this part of the problem, but at all times maintain a dedicated staff of monitoring in the practical application of the procedure is not possible; therefore, the security system for seamless connection management is the integration of system running efficiently, at present the museum security engineering practice, joint approach to the two systems, largely through the alarm system provides the functionality of the PGM output relay, and then transferred to access DVR or matrix of alarm input, disadvantages are very obvious, the first is affected by the alarm input quantity limit, if the zone number is large, the supplied alarm output PGM cannot distinguish in detail, DVR or matrix video timely response is relatively a blur effect to the discounted, unusual presents response errors may occur or not timely, the Museum this is high-grade security units.
Second, there is also CCTV system alarm input quantity restrictions that do not meet the alarm system requirements of large zone; at the same time, if a large number of alarm host, back-office software cannot adapt to a single software management and problems, if all of the telephone network outgoing or dedicated line 485 forms of transport costs and transport structure is complex, the stability of the system running safe and result of risks; and, third, and most major issues, alarm systems CCTV system of management and administration are relatively independent, Aviso happens, alarm system host make alarm reaction, but monitoring system can not be timely adjustment of camera location and video, which leads to inefficiency, if their duties are not in place, the consequences are very serious.In response to this reality, our many years of research and exploration, at present has formed a relatively complete resolution Museum to represent units of high grade security alarm video integration management programme, the following on this solution is the core of a few simple questions:
Alarm system: Posonic dual bus alarm host PS-9192 is a core part of this system, the host has a large zone extension capabilities, and Super remote transmission capacity, host defense from eight basic defense area, scales to 192 custom zone that hosts the number of supported system module is also very much, and can support up to 192 zones nature module, 48 control keyboard and a maximum of 64-channel relay output modules, and other features, such as the nature of the module that is dual-bus structure, on a special area (such as a floor or more centralized area) can choose multiple zone module (8-16 zone), a distance of 750 m, stretched through the power and relay extension module PS-483 double transmission distance; in some more in the long distance sector signal transmission, while you can use the bus driver modules, support 3-way PS-PP8 3Km transfer bus (no need to relay extension) that can add 1-4 zone module using, on the premises distributed Museum of police standoff resolved and perimeter processing can be completed, at the same address can be set 1-eight subsystems, according to the Museum's work and opening hours external conditions to determine reasonable combination of each subsystem to ensure that the security system of rationalization.
To consolidate management of alarm monitoring system aspects make the following brief introduction:
Control software: for establishment in the system of 9192 Admin software (security monitoring software), in addition to completing the normal program setting, Chief garrison, subsystems, and alarm handling, and other functions, you have the entire synchronization management CCTV system, linkage management software integration is now mainstream matrix brand and DVR, DVS brand communication protocols, set in the program, you can choose alarm event or zone event and CCTV system camera side and behind the scenes video management for contact and interaction, the corresponding event methods can be one-to-one, one-to-many or many-to-one or many-to-many, cross form, can be set at will according to the situation, the main purpose is to ensure that the warning event, live video of the first time, will not be subject to the then actions on duty officer's response capacity and proficiency, management system will automatically follow the various alarming situation in advance of the scheduled CCTV camera position adjustment and video start (or high-definition video), and other actions; when the alarm system has a zone alarm, CCTV camera (speed dome) automatically correspond to the position in the video, Defense computer interface automatically pop-up screen management duty staff directly on the screen to see alarm zone facts, based on field observation of events, select the appropriate approach greatly saving the staff took a video of the event.
This efficient management of events on Museum nature of security system of distribution: alarm forms of communication is through a host of SerilaOutput port and management computer 232 serial communication, support multiple alarm host work under the same software (such as a lack of 192 zone), the computer serial port extension; network matrices and DVR with LAN port and computer communications, matrix and more DVR is available through the router and computer communications; control software is built on the alarm system on the basis of the management control, communicate to the CCTV system; alarm system can be run as stand-alone, external remote telephone alarm still works, CCTV system continues to function in its own transport to continue to work, such as remote transmission and remote storage and access can complete normally.System diagram
The rationalization of the integrated management system is to protect the system set up running efficiently, while front-end detection equipment selection and use of the Museum and alarm system reliability of primary factors, for detection of stable and effective work is the whole security system effective work of the Foundation, the current domestic professional alarm equipment manufacturing
Also, we are also on the current international usually adopts some of the standard detection equipment Museum a simple introduction to facilitate broad peer reference:Content:
1. outdoor dual technology barrier
Outdoor dual technology barrier
Microwave and quarternary active infrared two detection technology, can be effective on the following factors produce false positives: birds, small animals, leaves and other floating matter, sunlight, high-frequency signal, as the walls of the emission of the signal, the illumination produced by the white light, etc., greatly improves the reliability of the system, while in the wind, rain, snow, fog, Thunder, electricity and other bad of environment also performed well.
Product itself high 2 m-4 m, according to the scene need to retrofit element infrared module, thereby contributing to the prevention of density.
In the product ends with a short microwave detection sources, to eliminate the blind spot of prevention.[1] [2] [3]